ERROR 2835 - Not expecting point for bc type: "<>".

Alternate Message
ERROR 2835 - Not expecting line for bc type: "<>".
ERROR 2835 - Not expecting region for bc type: "<>".

Message Type
ERROR

Description
Not expecting point / line / region for BC type: "<>". A point / line / region is not valid for the boundary condition (BC) type "<>".
From the 2023-03 release, a point-type QT boundary is not supported when using TUFLOW Classic / HPC (bringing the behaviour in line with Quadtree).

Suggestions

  • Refer to the TUFLOW Manual for information on the BC type "<>" and its specifications.
  • If a QT point was intended to be used as an internal inflow boundary, transitioning to a 2d_sa setup is recommended. For an external boundary, the preferred approach is to use a 2d_bc QT line snapped to the code polygon.


Up