TUFLOW Message 0038

From Tuflow
Revision as of 14:21, 13 January 2016 by Par (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 0038 - Could not apply Set IWL == AUTO due to varying 2D HT boundary. |alt_msg=NA |type=ERROR |message_desc=If using the <tt>Set IWL...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 0038 - Could not apply Set IWL == AUTO due to varying 2D HT boundary.

Alternate Message
NA

Message Type
ERROR

Description
If using the Set IWL == Auto feature, the IWL in the model is automatically set based on the water level at the downstream boundary. In this a varying HT boundary in the 2D model has been used and TUFLOW is unable to set the IWL automatically.

Suggestions
Ensure that only a single water level boundary is used or remove the Set IWL == Auto command and set the IWL manually using the Set IWL == <value>, Read GIS IWL == <gis layer> or Read Grid IWL == <grid dataset> commands.


Up