Line 9: Line 9:
  
 
Define Event Name == 100y
 
Define Event Name == 100y
     BC Event Source == _ARI_ \| 100y
+
     BC Event Source == _ARI_ {|} 100y
 
     Output Folder == ..\results_100y
 
     Output Folder == ..\results_100y
 
End Define
 
End Define

Revision as of 20:53, 4 August 2011

TUFLOW Message
ERROR 0029 - "End Define" found in incorrect location.

Alternate Message
NA

Message Type
ERROR

Description
An End Define command was found outside a Define Event == / End Define block.

Suggestions
Scan the console window or .tlf file to establish where TUFLOW is in the event file. Check the event file and locate the problematic End Define.

Tip: When using commands such as Define Event == indent the commands that follow. For example:

Define Event Name == 100y

   BC Event Source == _ARI_ {


Up
Go-up.png 0xxx Messages