TUFLOW Message 0046

From Tuflow
Revision as of 13:47, 17 February 2015 by Steph.dufour (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
ERROR 0046 - ????
WARNING 0046 - ????

Alternate Message
NA

Message Type
ERROR
WARNING

Description
The output interval has not been specified using the tcf commands Time Series Output Interval or Output Interval (s), when simulating the model with Build 2013-12-AA or later. TUFLOW will issue an ERROR when using the default settings for this build or a WARNING if Defaults == PRE 2013. This is a mandatory command as the default values for these intervals is the computational timestep, and by not specifying values can cause excessive amounts of memory to be allocated, sometimes causing undesirable results!

Suggestions
Specify the output interval using commands Time Series Output Interval or Output Interval (s).


Up
Go-up.png 0xxx Messages