|message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area.  If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective. <br>
 
|message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area.  If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective. <br>
 
<br>
 
<br>
'''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections.  The ''''one'''' of the following should be specified:<br>
+
'''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections.  The '''one''' of the following should be specified:<br>
 
'''“F”''' for a multiplication factor; or<br>
 
'''“F”''' for a multiplication factor; or<br>
 
'''“N”''' for a Manning’s n value.   
 
'''“N”''' for a Manning’s n value.   

Revision as of 15:34, 31 January 2011

TUFLOW Message
ERROR 1056 - Incompatible flags "E" and "T" specified for cross-section ",a," in ",a,

Alternate Message
ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,

Message Type
ERROR

Description
"E" and "T" are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an “E” to use effective area or a “T” to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective.

"F" and "N" are vertical change in resistance for CS or HW type cross-sections. The one of the following should be specified:
“F” for a multiplication factor; or
“N” for a Manning’s n value.

Suggestions
Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.