Difference between revisions of "TUFLOW Message 1092"

From Tuflow
Jump to navigation Jump to search
 
(2 intermediate revisions by the same user not shown)
Line 4: Line 4:
 
|type=[[ERROR]]<br>
 
|type=[[ERROR]]<br>
 
[[WARNING]]
 
[[WARNING]]
|message_desc=Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If '<font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012 </tt></font>' is set, a WARNING 1092 is issued and the model simulation will not stop.  
+
|message_desc=Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If <font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012 </tt></font> is set, a WARNING 1092 is issued and the model simulation will not stop.  
 
|suggestions=Check for a null or less than or equal to zero flow area within a Q pit.  
 
|suggestions=Check for a null or less than or equal to zero flow area within a Q pit.  
|discussion_page=* [[Talk:TUFLOW Message 1092|Discuss Message 1092]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_1091|Message 1091]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1093|Message 1093]]
 
 
}}
 
}}

Latest revision as of 15:09, 22 December 2022

TUFLOW Message
ERROR 1092 - No flow area provided for pit type ",a,".

Alternate Message
ERROR 1092 - Flow area provided for pit type or yQ curve "a" is less than or equal to zero.

Message Type
ERROR
WARNING

Description
Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If Defaults == Pre-2012 is set, a WARNING 1092 is issued and the model simulation will not stop.

Suggestions
Check for a null or less than or equal to zero flow area within a Q pit.


Up
Go-up.png 1xxx Messages