TUFLOW Message 1118

From Tuflow
Revision as of 15:17, 22 December 2022 by Melissa1987 (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
ERROR 1118 - Could not find pit inlet type ",a," in the pit inlet database.

Alternate Message
NA

Message Type
ERROR

Description
For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples see Section 4.5.1.2 (Pit Inlet Database) of the TUFLOW manual (2010 version).

Suggestions
Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified.


Up
Go-up.png 1xxx Messages