Difference between revisions of "TUFLOW Message 1253"

From Tuflow
Jump to navigation Jump to search
m
 
(5 intermediate revisions by 3 users not shown)
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[WARNING]]
 
|type=[[WARNING]]
|message_desc=Unused data in table links (<tt>Read GIS Table Links == </tt>).  A unused link to tabular input has been found, tabular data can include cross-section profiles, cross-section hydraulic parameters, nodal surface areas or bridge loss coefficients.  This can occur if a cross-section with three or more vertices isn't snapped to a 1D network (1d_nwk) or doesn't intersect 1d_nwk line for a two vertix line.
+
|message_desc=Unused data in table links (<tt>Read GIS Table Links == </tt>).  A unused link to tabular input has been found, tabular data can include cross-section profiles, cross-section hydraulic parameters, nodal surface areas or bridge loss coefficients.   
|suggestions=Check if the 1d_ta object should be unused.
+
This can occur if:
|discussion_page=* [[Talk:TUFLOW Message 1253|Discuss Message 1253]]
+
* A 1d_ta element with three or more vertices isn't snapped to a 1D network (1d_nwk) node
|link3=''
+
* A 1d_ta element with two vertices does not  intersect 1D network (1d_nwk) line
|link4=''
+
* A channel in the 1D network has both end and mid cross sections
|prelink=[[TUFLOW_Message_1252|Message 1252]]
+
* Two or more 1d_ta elements exist in the same location
 +
|suggestions=
 +
* Check if the 1d_ta object is linked to the 1D network (either snapped for a 1d_ta object with 3 or more vertices or just intersecting if the 1d_ta object has only 2 vertices)
 +
* Check if the 1D network channel has both mid- and end- cross-sections. If both mid- and end- sections exist, TUFLOW will ignore the end-cross-sections in favour of the mid-cross-sections (Refer to the Mid Cross-Section and End Cross-section Chapters of the TUFLOW Manual)
 +
*  Check if cross-sections are both in the same location
 +
 
 +
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1255|Message 1255]]
 
 
}}
 
}}

Latest revision as of 15:58, 22 December 2022

TUFLOW Message
WARNING 1253 - Unused 1d_ta line with attributes: ",a,",

Alternate Message
NA

Message Type
WARNING

Description
Unused data in table links (Read GIS Table Links == ). A unused link to tabular input has been found, tabular data can include cross-section profiles, cross-section hydraulic parameters, nodal surface areas or bridge loss coefficients. This can occur if:

  • A 1d_ta element with three or more vertices isn't snapped to a 1D network (1d_nwk) node
  • A 1d_ta element with two vertices does not intersect 1D network (1d_nwk) line
  • A channel in the 1D network has both end and mid cross sections
  • Two or more 1d_ta elements exist in the same location

Suggestions

  • Check if the 1d_ta object is linked to the 1D network (either snapped for a 1d_ta object with 3 or more vertices or just intersecting if the 1d_ta object has only 2 vertices)
  • Check if the 1D network channel has both mid- and end- cross-sections. If both mid- and end- sections exist, TUFLOW will ignore the end-cross-sections in favour of the mid-cross-sections (Refer to the Mid Cross-Section and End Cross-section Chapters of the TUFLOW Manual)
  • Check if cross-sections are both in the same location


Up
Go-up.png 1xxx Messages