Difference between revisions of "TUFLOW Message 1343"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1343 - In ',A4,1X,a,' table above, Column 1 values not increasing. Values: ',a,' then |alt_msg=NA |type=ERROR |message_desc=???? |sug...')
 
 
(2 intermediate revisions by 2 users not shown)
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=The value in column 1 of the 1d_ta file does not increase as it progresses, as shown in the example below. This is usually the 'X' value for an XZ type table; or 'H' value for a HW type table.
|suggestions=????
+
<br>
|discussion_page=* [[Talk:TUFLOW Message 1343|Discuss Message 1343]]
+
[[File:Non-incremental_HW_Table.png|320px]]
|link3=''
+
<br>
|link4=''
+
|suggestions=If there is a stepped increment in the 1d cross-section that you are trying to represent; it is possible to resolve this error by using a small increment of a millimetre between values in column 1 of the 1d_ta file.
|prelink=[[TUFLOW_Message_1342|Message 1342]]
+
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1344|Message 1344]]
 
 
}}
 
}}

Latest revision as of 10:34, 23 December 2022

TUFLOW Message
ERROR 1343 - In ',A4,1X,a,' table above, Column 1 values not increasing. Values: ',a,' then

Alternate Message
NA

Message Type
ERROR

Description
The value in column 1 of the 1d_ta file does not increase as it progresses, as shown in the example below. This is usually the 'X' value for an XZ type table; or 'H' value for a HW type table.
Non-incremental HW Table.png

Suggestions
If there is a stepped increment in the 1d cross-section that you are trying to represent; it is possible to resolve this error by using a small increment of a millimetre between values in column 1 of the 1d_ta file.


Up
Go-up.png 1xxx Messages