Difference between revisions of "TUFLOW Message 1423"

From Tuflow
Jump to navigation Jump to search
Line 5: Line 5:
 
|message_desc=Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.
 
|message_desc=Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.
 
|suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.
 
|suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.
|discussion_page=* [[Talk:TUFLOW Message 1423|Discuss Message 1423]]
+
 
|link3=''
 
|link4=''
 
 
|prelink=[[TUFLOW_Message_1422|Message 1422]]
 
|prelink=[[TUFLOW_Message_1422|Message 1422]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|nextlink=[[TUFLOW_Message_1425|Message 1425]]
 
|nextlink=[[TUFLOW_Message_1425|Message 1425]]
 
}}
 
}}

Revision as of 15:47, 5 July 2022

TUFLOW Message
ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>

Alternate Message
N/A

Message Type
ERROR

Description
Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.

Suggestions
Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.


Up
Go-up.png 1xxx Messages