Difference between revisions of "TUFLOW Message 1510"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=CHECK 1402 - More than one culvert connected but could not create manhole at Node <Node ID> |alt_msg=NA |type=CHECK |message_desc=When app...")
 
 
(7 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=CHECK 1402 - More than one culvert connected but could not create manhole at Node <Node ID>
+
|tuflow_message=ERROR 1510 - Invalid condition specified in operating control rule below.
 
|alt_msg=NA
 
|alt_msg=NA
|type=[[CHECK]]
+
|type=[[ERROR]]
|message_desc=When applying the Engelhund loss approach for manholes (see Section 4.5.2 of the 2010 TUFLOW manual), if an incoming culvert enters above the obvert of the highest outlet, the culvert is not included in the manhole loss calculations.  If there is only 1 incoming pipe with the invert above the obvert of the outlet culvert, the incoming culvert is ignored and with no inlet culvert to the node a manhole is not possible.  See also point 48(b) in the [http://www.tuflow.com/Download/TUFLOW/Releases/2012-05/Doc/TUFLOW%20Release%20Notes.2011-09%20and%202012-05.pdf release notes].
+
|message_desc=The command specified within the .toc file is invalid.  
|suggestions=Review the inverts on the culverts.  A point object in a "1d_mh" layer can be used to set the loss approach at each manhole.
+
|suggestions=The command producing the error will be outputted to the tlf file following the initial ERROR message. Check the syntax of the command line against guidance provided the TUFLOW Manual.
|discussion_page=* [[Talk:TUFLOW Message 1510|Discuss Message 1510]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_1402|Message 1402]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1527|Message 1527]]
 
 
}}
 
}}

Latest revision as of 10:47, 23 December 2022

TUFLOW Message
ERROR 1510 - Invalid condition specified in operating control rule below.

Alternate Message
NA

Message Type
ERROR

Description
The command specified within the .toc file is invalid.

Suggestions
The command producing the error will be outputted to the tlf file following the initial ERROR message. Check the syntax of the command line against guidance provided the TUFLOW Manual.


Up
Go-up.png 1xxx Messages