Difference between revisions of "TUFLOW Message 1527"

From Tuflow
Jump to navigation Jump to search
Line 8: Line 8:
 
|link3=''
 
|link3=''
 
|link4=''
 
|link4=''
|prelink=[[TUFLOW_Message_1510|Message 1510]]
+
|prelink=[[TUFLOW_Message_1522|Message 1522]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|nextlink=[[TUFLOW_Message_1991|Message 1991]]
 
|nextlink=[[TUFLOW_Message_1991|Message 1991]]
 
}}
 
}}

Revision as of 01:42, 23 June 2015

TUFLOW Message
ERROR 1527 - Could not find Operating Control Definition for Channel 'a'.

Alternate Message
NA

Message Type
ERROR

Description
The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found.

Suggestions
Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and “Define Control ==”…“End Define” logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic.


Up
Go-up.png 1xxx Messages