Difference between revisions of "TUFLOW Message 1625"

From Tuflow
Jump to navigation Jump to search
 
(5 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=CHECK 1625 - Unconnected pit
+
|tuflow_message=CHECK 1625 - Unconnected pit.
|alt_msg=NA
+
|alt_msg=CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use <font color="blue"><tt>PIT NO 1D CONNECTION </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>ERROR</tt></font>.
 
|type=[[CHECK]]
 
|type=[[CHECK]]
|message_desc=Pit is not snapped or within the <font color="blue"><tt>Pit Search Distance </tt></font> <font color="red"><tt>==</tt></font>.
+
|message_desc=Pit is not snapped or within the <font color="blue"><tt>Pit Search Distance </tt></font> <font color="red"><tt>==</tt></font>, and will be modelled as an 1D virtual pipe.
|suggestions=Check the pit connection. See also [[Talk:TUFLOW Message 1625|Discuss Message 1625]].
+
|suggestions=If the pit must be connected to a 1D channel, use the ECF command <font color="blue"><tt>Pit No 1D Connection </tt></font> <font color="red"><tt>==</tt></font> ERROR to force an error and check the pit connection. See also <u>[[TUFLOW_Message_1626|ERROR 1626]]</u>.
|discussion_page=* [[TUFLOW_Message_1626|ERROR 1626]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_1621|Message 1621]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1626|Message 1626]]
 
 
}}
 
}}

Latest revision as of 10:49, 23 December 2022

TUFLOW Message
CHECK 1625 - Unconnected pit.

Alternate Message
CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR.

Message Type
CHECK

Description
Pit is not snapped or within the Pit Search Distance ==, and will be modelled as an 1D virtual pipe.

Suggestions
If the pit must be connected to a 1D channel, use the ECF command Pit No 1D Connection == ERROR to force an error and check the pit connection. See also ERROR 1626.


Up
Go-up.png 1xxx Messages