Difference between revisions of "TUFLOW Message 2027"

From Tuflow
Jump to navigation Jump to search
Line 4: Line 4:
 
|type=[[ERROR]]
 
|type=[[ERROR]]
 
|message_desc=Found more than one 1D node snapped to 2D SX boundary.
 
|message_desc=Found more than one 1D node snapped to 2D SX boundary.
|suggestions=????
+
|suggestions=Review boundary configuration. Seperate 2D SX objects should be used for seperate nodes, or link nodes using a "X" type 1D network channel and have only one SX object.
 
|discussion_page=* [[Talk:TUFLOW Message 2027|Discuss Message 2027]]
 
|discussion_page=* [[Talk:TUFLOW Message 2027|Discuss Message 2027]]
 
|link3=''
 
|link3=''

Revision as of 16:35, 6 February 2011

TUFLOW Message
ERROR 2027 - Found more than one 1D node snapped to 2D SX object.

Alternate Message
NA

Message Type
ERROR

Description
Found more than one 1D node snapped to 2D SX boundary.

Suggestions
Review boundary configuration. Seperate 2D SX objects should be used for seperate nodes, or link nodes using a "X" type 1D network channel and have only one SX object.


Up
Go-up.png 2xxx Messages