Difference between revisions of "TUFLOW Message 2043"

From Tuflow
Jump to navigation Jump to search
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
 
|tuflow_message=ERROR 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.
 
|tuflow_message=ERROR 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.
|alt_msg=ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit.  Flows from 2D HX cells can only be assigned to ISIS RIVER units.
+
|alt_msg=ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit.  Flows from 2D HX cells can only be assigned to ISIS RIVER units.<BR>
|type=[[ERROR]]
+
WARNING 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.
 +
|type=[[ERROR]]<br>
 +
[[WARNING]]
 
|message_desc=2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model.
 
|message_desc=2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model.
|suggestions= Check the node type within the ISIS .dat file and remove connection (CN) lines within the 2d_bc layer at any non-RIVER/INTERPOLATE units.  
+
|suggestions= Check the node type within the ISIS .dat file and remove connection (CN) lines within the 2d_bc layer at any non-RIVER/INTERPOLATE units.<br>
|discussion_page=* [[Talk:TUFLOW Message 2043|Discuss Message 2043]]
+
Since TUFLOW built 2018-03-AC this error can be changed into warning by using command <font color="blue"><tt>SX FMP Unit Type Error</tt></font> <font color="red"><tt>== </tt></font> OFF.
|link3=''
+
 
|link4=''
 
|prelink=[[TUFLOW_Message_2042|Message 2042]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2044|Message 2044]]
 
 
}}
 
}}

Latest revision as of 11:13, 23 December 2022

TUFLOW Message
ERROR 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.

Alternate Message
ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit. Flows from 2D HX cells can only be assigned to ISIS RIVER units.
WARNING 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.

Message Type
ERROR
WARNING

Description
2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model.

Suggestions
Check the node type within the ISIS .dat file and remove connection (CN) lines within the 2d_bc layer at any non-RIVER/INTERPOLATE units.
Since TUFLOW built 2018-03-AC this error can be changed into warning by using command SX FMP Unit Type Error == OFF.


Up
Go-up.png 2xxx Messages