TUFLOW Message 2060

From Tuflow
Revision as of 15:22, 11 February 2011 by tuflow>Par
Jump to navigation Jump to search

TUFLOW Message
ERROR 2061 - Could not find a CN connection snapped to the end of HX line.

Alternate Message
NA

Message Type
ERROR

Description
Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain.

Suggestions
Ensure that there is a CN object at each end of HX line connecting HX line to 1D node.


Up
Go-up.png 2xxx Messages