|tuflow_message=????
+
|tuflow_message=WARNING 2074 - SA object does not select any 2D cells (active or inactive).
|message_desc=SA object does not select any 2D cells (active or inactive).
+
|alt_msg=NA
|suggestions=????
+
|type=[[WARNING]]
|discussion_page=* [[Talk:TUFLOW Message 2074|Discuss Message 2074]]
+
|message_desc=SA object does not select any 2D cells (active or inactive). For example this could occur when a 2d_sa object is located outside of the active model area. This warning may also occur if the digitised SA polygon does not select any cell centres (ZC points), in the figure below the polygon highlighted in pink does not contain any cell centres and therefore this warning message will be returned.<br>
|link3=''
+
[[File:WARNING 2074.jpg|600px]]
|link4=''
+
|suggestions=Check SA object and ensure that it is an active model area and selects at least one ZC zpt, or chose a different inflow location.
|prelink=[[TUFLOW_Message_2073|Message 2073]]
+
 
|nextlink=[[TUFLOW_Message_2075|Message 2075]]
+
 
 +
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
}}
 
}}

Latest revision as of 11:57, 23 December 2022

TUFLOW Message
WARNING 2074 - SA object does not select any 2D cells (active or inactive).

Alternate Message
NA

Message Type
WARNING

Description
SA object does not select any 2D cells (active or inactive). For example this could occur when a 2d_sa object is located outside of the active model area. This warning may also occur if the digitised SA polygon does not select any cell centres (ZC points), in the figure below the polygon highlighted in pink does not contain any cell centres and therefore this warning message will be returned.
WARNING 2074.jpg

Suggestions
Check SA object and ensure that it is an active model area and selects at least one ZC zpt, or chose a different inflow location.


Up
Go-up.png 2xxx Messages