Difference between revisions of "TUFLOW Message 2132"

From Tuflow
Jump to navigation Jump to search
Line 5: Line 5:
 
|message_desc=The node ID within a GIS layer read into TUFLOW must be unique and match the external 1D model exactly.
 
|message_desc=The node ID within a GIS layer read into TUFLOW must be unique and match the external 1D model exactly.
 
|suggestions=  Check for duplicate node names within the GIS layer. Confirm spelling of node ID exactly matches the external 1D model. Note that for node IDs within ISIS models are case sensitive, hence are also case sensitive when linked in an ISIS-TUFLOW models.  
 
|suggestions=  Check for duplicate node names within the GIS layer. Confirm spelling of node ID exactly matches the external 1D model. Note that for node IDs within ISIS models are case sensitive, hence are also case sensitive when linked in an ISIS-TUFLOW models.  
|discussion_page=* [[Talk:TUFLOW Message 2132|Discuss Message 2132]]
+
 
|link3=''
 
|link4=''
 
 
|prelink=[[TUFLOW_Message_2131|Message 2131]]
 
|prelink=[[TUFLOW_Message_2131|Message 2131]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|nextlink=[[TUFLOW_Message_2133|Message 2133]]
 
|nextlink=[[TUFLOW_Message_2133|Message 2133]]
 
}}
 
}}

Revision as of 13:39, 6 July 2022

TUFLOW Message
ERROR 2132 - Node is duplicated or does not exist in external 1D domain.

Alternate Message
NA

Message Type
ERROR

Description
The node ID within a GIS layer read into TUFLOW must be unique and match the external 1D model exactly.

Suggestions
Check for duplicate node names within the GIS layer. Confirm spelling of node ID exactly matches the external 1D model. Note that for node IDs within ISIS models are case sensitive, hence are also case sensitive when linked in an ISIS-TUFLOW models.


Up
Go-up.png 2xxx Messages