|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
 
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
  
|prelink=[[TUFLOW_Message_2214|Message 2214]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2216|Message 2216]]
 
 
}}
 
}}

Latest revision as of 14:11, 7 February 2023

TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.

Alternate Message
NA

Message Type
WARNING

Description
A 1D pit object can be connected to a maximum of 10 2D cells.

Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.


Up