Difference between revisions of "TUFLOW Message 2216"

From Tuflow
Jump to navigation Jump to search
 
Line 6: Line 6:
 
|suggestions=Review pit location, active 2D cells and number of cells TUFLOW is connecting to.  The number of cells automatically connects to can be controlled with the Conn_No attribute in the 1d_nwk layer.  Alternatively a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
 
|suggestions=Review pit location, active 2D cells and number of cells TUFLOW is connecting to.  The number of cells automatically connects to can be controlled with the Conn_No attribute in the 1d_nwk layer.  Alternatively a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
  
|prelink=[[TUFLOW_Message_2215|Message 2215]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2217|Message 2217]]
 
 
}}
 
}}

Latest revision as of 14:12, 7 February 2023

TUFLOW Message
ERROR 2216 - Could not find enough 2D cells to spread 1D pit connection over.

Alternate Message
NA

Message Type
ERROR

Description
TUFLOW automatically connects 1D pit objects to 2D cells using a on-grade or sag approach. TUFLOW has been unable to find enough active cells to connect pit to. For more details on connecting 1D pits to 2D domain see Section 4.5.1.3 of 2010 TUFLOW manual.

Suggestions
Review pit location, active 2D cells and number of cells TUFLOW is connecting to. The number of cells automatically connects to can be controlled with the Conn_No attribute in the 1d_nwk layer. Alternatively a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.


Up
Go-up.png 2xxx Messages