TUFLOW Message
ERROR 2436 - Sending hydrograph weights to HPC Solver.

Alternate Message
NA

Message Type
ERROR

Description
Hydrographs were not accepted by the HPC solver. Prior to 2020-10-AA release this error was caused by multiplication factors f1 and f2 in the 2d_rf layer other than 1.

Suggestions
Use the latest TUFLOW release. If multiplication factors other than 1 are used and TUFLOW version cannot be updated, multiplication should be applied to the source hydrographs rather than the factors f1 and f2.