TUFLOW Message 2460

From Tuflow
Revision as of 13:04, 21 February 2011 by Bill Syme (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
WARNING 2460 - RF f1 and/or f2 attribute set to zero - no rainfall will be applied.

Alternate Message
WARNING 2460 - SA RF Catchment_Area and/or Rain_Gauge_Factor attribute set to zero - no rainfall will be applied.

Message Type
WARNING

Description
????

Suggestions
Check that the attribute(s) should have a zero value otherwise no rainfall for this GIS object will be applied during the simulation. This WARNING occurs where the user has accidentally forgotten to assign values to the attribute(s) as the default setting for these attributes if using a GIS is zero.


Up
Go-up.png 2xxx Messages