Difference between revisions of "TUFLOW Message 2467"

From Tuflow
Jump to navigation Jump to search
 
(3 intermediate revisions by 3 users not shown)
Line 4: Line 4:
 
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.<br>
 
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.<br>
 
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.
 
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.
|type=[[CHECK]], [[ERROR]]
+
|type=[[CHECK]]<br>[[ERROR]]
 
|message_desc=A cell side encountered overlapping flow constrictions.
 
|message_desc=A cell side encountered overlapping flow constrictions.
|suggestions=Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. From 2022 release, overlapping flow constriction triggers an error.
+
|suggestions=From 2023 release, overlapping flow constriction triggers an error.<br> Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. <br>
 +
 
 +
 
  
|prelink=[[TUFLOW_Message_2466|Message 2466]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2468|Message 2468]]
+
 
 
}}
 
}}

Latest revision as of 09:20, 25 August 2023

TUFLOW Message
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.

Alternate Message
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.

Message Type
CHECK
ERROR

Description
A cell side encountered overlapping flow constrictions.

Suggestions
From 2023 release, overlapping flow constriction triggers an error.
Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions.


Up
Go-up.png 2xxx Messages