Difference between revisions of "TUFLOW Message 3011"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 3011: Target control number must be in range 0.001 - 1.2. <br> |alt_msg=None |type=ERROR |message_desc=The wet/dry depth threshol...")
 
 
(3 intermediate revisions by 3 users not shown)
Line 5: Line 5:
  
 
|type=[[ERROR]]  
 
|type=[[ERROR]]  
|message_desc=The wet/dry depth threshold has been set to a value below the minimum allowed.
+
|message_desc=This error message has been deprecated. If you are still receiving this message with the latest TUFLOW release, please contact [mailto:support@tuflow.com support@tuflow.com].<br>
|suggestions=
+
The Control Number Factor must be in the range 0.001 - 1.2.  
The minimum permissible target timestep allowed for the HPC Solver is set with the 'Timestep Minimum' TCF command, where the default is the minimum of 0.1 seconds or the cell size divided by 200 m/s. This value must be less than the initial timestep value specified for the HPC Solver with the 'Timestep' or 'Timestep Intitial' TCF commands. The timestep can also not be less than 0.000001s.
+
|suggestions=Ensure the 'Control Number Factor' TCF command is within the range 0.001 - 1.2. The default value is 1.0.
 +
 
 +
Whilst it is possible to increase the default HPC Courant, shallow wave celerity and diffusion control numbers (effectively overclocking the simulation), it is strongly recommended not to increase the Control Number Factor above the default of 1.0. A hard upper limit has been set to prevent an increase of more than 20% (i.e. Control Number Factor == 1.2). Increasing control numbers by more than this would be likely to lead to instability.
 +
 
  
|discussion_page=* [[Talk:TUFLOW Message 3011|Discuss Message 3011]]
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_3010|Message 3010]]
 
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|nextlink=[[TUFLOW_Message_3012|Message 3012]]
 
 
}}
 
}}

Latest revision as of 10:11, 3 March 2023

TUFLOW Message
ERROR 3011: Target control number must be in range 0.001 - 1.2.

Alternate Message
None

Message Type
ERROR

Description
This error message has been deprecated. If you are still receiving this message with the latest TUFLOW release, please contact support@tuflow.com.
The Control Number Factor must be in the range 0.001 - 1.2.

Suggestions
Ensure the 'Control Number Factor' TCF command is within the range 0.001 - 1.2. The default value is 1.0.

Whilst it is possible to increase the default HPC Courant, shallow wave celerity and diffusion control numbers (effectively overclocking the simulation), it is strongly recommended not to increase the Control Number Factor above the default of 1.0. A hard upper limit has been set to prevent an increase of more than 20% (i.e. Control Number Factor == 1.2). Increasing control numbers by more than this would be likely to lead to instability.