Difference between revisions of "TUFLOW Message 3506"

From Tuflow
Jump to navigation Jump to search
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=CHECK 3506: Limiting SGS Grid sample frequency to upper limit of 'a'., sample distance of 'b'.
+
|tuflow_message=CHECK 3506 - Limiting SGS Grid sample frequency to upper limit of 'a'., sample distance of 'b'.
 
<br>  
 
<br>  
|alt_msg=N/A
+
|alt_msg=CHECK 3506 - Limiting SGS sample frequency to lower limit of 'a', from 'b'.
  
 
|type=[[CHECK]]  
 
|type=[[CHECK]]  
|message_desc=Too high SGS sample frequency can result into long pre-processing time, and users may not benefit from applying a super fine sample distance against the model cell size. In general we found a sample frequency smaller than 31 is sufficient for most of natural water ways or artificial structures, and the default frequency limit is set as 31.
+
|message_desc=Too high SGS sample frequency can result into long pre-processing time, and users may not benefit from applying a super fine sample distance against the model cell size. In general we found a sample frequency smaller than 31 is sufficient for most of natural water ways or artificial structures, and the default frequency limit is set as 31.<br>
 +
The minimum limit of SGS sample frequency is 3. Anything below that will be adjusted to 3.
 
|suggestions=The default limit can be changed by using a second argument in the <font color="blue"><tt>SGS Grid/TIN Sample Distance</tt></font> command, e.g. <font color="blue"><tt>SGS Grid Sample Distance</tt></font> <font color="red"><tt>== </tt></font> <tt>1</tt> I <tt>51</tt> sets the sampling distance to 1 m and the frequency limit to 51 for grids. The frequency limit does round up to the nearest odd number.
 
|suggestions=The default limit can be changed by using a second argument in the <font color="blue"><tt>SGS Grid/TIN Sample Distance</tt></font> command, e.g. <font color="blue"><tt>SGS Grid Sample Distance</tt></font> <font color="red"><tt>== </tt></font> <tt>1</tt> I <tt>51</tt> sets the sampling distance to 1 m and the frequency limit to 51 for grids. The frequency limit does round up to the nearest odd number.
 
|discussion_page=* [[Talk:TUFLOW Message 3506|Discuss Message 3506]]
 
|discussion_page=* [[Talk:TUFLOW Message 3506|Discuss Message 3506]]

Revision as of 13:44, 13 July 2021

TUFLOW Message
CHECK 3506 - Limiting SGS Grid sample frequency to upper limit of 'a'., sample distance of 'b'.

Alternate Message
CHECK 3506 - Limiting SGS sample frequency to lower limit of 'a', from 'b'.

Message Type
CHECK

Description
Too high SGS sample frequency can result into long pre-processing time, and users may not benefit from applying a super fine sample distance against the model cell size. In general we found a sample frequency smaller than 31 is sufficient for most of natural water ways or artificial structures, and the default frequency limit is set as 31.
The minimum limit of SGS sample frequency is 3. Anything below that will be adjusted to 3.

Suggestions
The default limit can be changed by using a second argument in the SGS Grid/TIN Sample Distance command, e.g. SGS Grid Sample Distance == 1 I 51 sets the sampling distance to 1 m and the frequency limit to 51 for grids. The frequency limit does round up to the nearest odd number.


Up
Go-up.png 3xxx Messages