TUFLOW Message 3519

From Tuflow
Revision as of 10:34, 9 February 2021 by ShuangGao (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
CHECK 3519: Using MIN or GULLY option in SGS model.

Alternate Message
NA

Message Type
CHECK applies a gradient along the face based on the cell corners and cell side Zpt values and for thick lines uses the ZC, ZU, ZV and ZH values to apply a sloping cell area for the cell volume.

Description
If the DEM's resolution is fine enough, SGS can preserve the flow path along the cells/faces without using any gully line. By default, a gully line applies a gradient along the faces based on the cell corners and cell side Zpt values, and creates sloping cells using the ZC, ZU, ZV and ZH values. It dose insure a continuous flow path, but the spatial accuracy may become lower comparing to the approach of sampling elevation directly from DEM.

Suggestions
Check if "SGS Sample Distance" and resolution of the DEM is fine enough to capture the gully line. If so, the topography modification MIN or GULLY option can be removed.


Up
Go-up.png 3xxx Messages