Check Files 2d uvpt

From Tuflow
Jump to navigation Jump to search

Introduction

This GIS file contains information about the cell sides (U and V points).

Attributes of _uvpt_check

General Attributes

Attribute Name Attribute Description
n Row number in the TUFLOW domain.
m Column number in the TUFLOW domain.
Type Zpt type (U or V).
Init_Vel Initial Velocity.
Mannings_n (default)
Chezy_Coeff
Mannings_M
Roughness coefficient.
FLC Additional form loss applied.
WrF Weir factor.
FC_Depth_to_Lid (only if the model has flow constrictions) For flow constrictions, the depth to the obvert.
FC_BD_Factor (only if the model has flow constrictions) For flow constrictions, the bridge deck factor.
FC_Width_Factor (only if the model has flow constrictions) For flow constrictions, the flow width factor.
Domain_Index The index of the model domain. This is the order with Start 2D Domain == <Domain Name> commands appears in the TCF control file. For a single domain model this will be 1.
Example _uvpt_check attribute table:
2d uvpt Reg attribute table 01.png


Attributes when using quadtree

Attribute Name Attribute Description
qpc_id The quadtree cell ID.
Type Zpt type (U or V).
Init_Vel Initial Velocity.
Mannings_n (default)
Chezy_Coeff
Mannings_M
Roughness coefficient.
Example _uvpt_check attribute table (using Quadtree):
2d uvpt Quad attribute table 01.png


Features

The image below shows the _uvpt_check styled by the Manning's n value. Note if using depth varying varying roughness the Material ID attribute in the _grd_check file may be preferred.

Check Files uvpt n 01.jpg


Up
Go-up.png TUFLOW Check Files