CHECK 0248 - encountered <>, <> as first field name - typically this should only be present in GPKG layers.

Alternate Message
WARNING 0248 - encountered <>, <> as first field name - typically this should only be present in GPKG layers.
ERROR 0248 - encountered <>, <> as first field name - typically this should only be present in GPKG layers. Use "GPKG Conversion Check == WARNING" to change message to a WARNING.

Message Type
CHECK
WARNING
ERROR

Description
Encountered <>, <> as first field name - typically this should only be present in GPKG layers.

Suggestions
This message may occur when reading a SHP or MIF file that has been exported from a GKPG layer.
Use "GPKG Conversion Check == WARNING" to change message to a WARNING.

Alternatively, ensure the input file follows the correct TUFLOW attributes, this may require deleting the first field. You can reference the correct TUFLOW attributes in the template GIS layers saved in the TUFLOW\model\gis\empty folder.
If an empty folder does not exist, it can be generated using the Create/Configure Project QGIS tool.