TUFLOW Message 1278

From Tuflow
Jump to navigation Jump to search

TUFLOW Message
ERROR 1278 - Pit <pit ID> inlet level is below lowest channel/pipe bed.
ERROR 1278 - Pit Entry Level = <value>; Lowest Channel/Pipe Invert = <value>

Alternate Message
WARNING 1278 - Pit <pit ID> inlet level is below lowest channel/pipe bed.

Message Type
ERROR
WARNING

Description
The inlet level for the pit is below the lowest connect channel / culvert.

Suggestions

  • Check inputs and ensure that invert levels are being correctly specified.
  • If US_Invert is set to -99999, run the model in a test mode without any 1D elements, 1D/2D links and other 1D related features to produce zpt_check file. Review if Zpts elevation at pit location is reasonable.
  • 1D elements can still be read into the model even if they fall outside the 2d_code polygon, provided they are within the model domain. This can result in ERROR 1278 if TUFLOW attempts to assign a 2D elevation at the 1D element’s location (e.g. for pits with any SX attribute where the US_Invert is set to be read or calculated from the 2D elevation) but no 2D cells are available. Removing unnecessary 1D elements that fall outside the active 2D area may resolve the error.

SGS model: Users may receive this error after converting a working non-SGS model to an SGS model. In a non-SGS model, the cell elevations are sampled at the cell centres, while an SGS model samples DEM elevations inside the cells based on the SGS sample distance and uses the lowest elevation inside the cell as the “pit inlet level”. Therefore, an SGS model might have picked up an elevation lower than the pipe invert level. In such case, the "US_Invert" attribute of the 1d_nwk GIS layer can be used to manually specify the ground elevation of the pit. If possible, it is also suggested to review the cell size of the model, so that the model doesn't sample an elevation far away from the pit.


Up