ERROR 1289 - ESTRY command in above line is unrecognisable.
Alternate Message 
NA
Message Type 
ERROR
Description 
The ESTRY command is not recognised by TUFLOW.
Suggestions 
There are two primary reasons this may occur:
- Incorrect spelling / syntax of TUFLOW command
- Trying to use an unsupported fixed field input
Locate the message in the console window or TUFLOW log file.  Check that this is a valid command, e.g. "Read GIS Network" and not "Raed GIS Network".
Check that the model contains no fixed field inputs.  Fixed field inputs typically look like the below:
CS     206    2    
    -2.200     3.310
     30.00     50.00
NA     101    3
        0.       10.       30.
   200000.   500000.  1000000.  
NAR    201  200
As of the 2010 version of TUFLOW these fixed field inputs are no longer supported by TUFLOW. These will need to be converted to the 1d_tab format, or a previous version of TUFLOW used.