TUFLOW Message 1298
		
		
		
		Jump to navigation
		Jump to search
		
TUFLOW Message 
WARNING 1298 - 1D timestep must be less than or equal to smallest timestep from the 2D domains
Alternate Message 
NA
Message Type 
WARNING
Description 
1D timestep must be must be less than or equal to the timestep of the 2D model.  If multiple 2D domains are used the 1D timestep must be less than or equal to the smallest timestep in any of the 2D domains.  If using a 1D timestep smaller than  2D timestep, the 2D timestep needs to be divisible by the 1D timestep.  For example a with a 2D timestep of 4 seconds a 1D timestep of 1 or 2 seconds is ok, but 2.5 not valid.
Suggestions 
Specify a 1D timestep less than or equal to the 2D timestep or the smallest 2D timestep for a multiple 2D domain model.