TUFLOW Message 1402
		
		
		
		Jump to navigation
		Jump to search
		
TUFLOW Message 
CHECK 1402 - More than one culvert connected but could not create manhole at Node <Node ID>
Alternate Message 
NA
Message Type 
CHECK
Description 
When applying the Engelhund loss approach for manholes (refer to the TUFLOW Manual), if an incoming culvert enters above the obvert of the highest outlet, the culvert is not included in the manhole loss calculations.  If there is only 1 incoming pipe with the invert above the obvert of the outlet culvert, the incoming culvert is ignored and with no inlet culvert to the node a manhole is not possible.
Suggestions 
Review the inverts on the culverts.  A point object in a "1d_mh" layer can be used to set the loss approach at each manhole.