TUFLOW Message 1470

From Tuflow
Jump to navigation Jump to search

TUFLOW Message
WARNING 1470 - Neither Gate Speed nor Period Opening/Closing is specified. Assuming Period Opening/Closing of 60 sec for XXX Control: <control_name>

Alternate Message
CHECK 1470 - Both Gate Speed nor Period Opening/Closing is specified. Assuming Period Opening/Closing of 60 sec for XXX Control: <control_name>

Message Type
WARNING
CHECK

Description
Both Gate Speed and Period Opening/Closing commands can define operational speed of gated structures.

  • if neither command is specified, the default Period Opening/Closing of 60 sec is used to set the Gate Speed
  • if both commands are specified, Period Opening/Closing is ignored and Gate Speed is used

The same rule applies to the Weir Height/Width Speed commands for operational weirs.

Suggestions
Check toc file input to ensure that the operational control works as intended.


Up
1xxx Messages