TUFLOW Message 2016
Jump to navigation
Jump to search
TUFLOW Message
ERROR 2016 - Unrecognisable 2D connection specified for pit or manhole.
Alternate Message
NA
Message Type
ERROR
Description
Unrecognisable 2D connection specified for pit or manhole.
Suggestions
The Conn_2D attribute in the 1d_nwk can be used to create a 2D connection. Valid options are:
- SX
- SXZ
- SXL
- SXG
- SXS
For more information on these, refer to the TUFLOW Manual.
If you are using th GPU virtual pipes feature, this error may occur if you have spcified the 'Width' or 'Conn_No' as Zero
Up |
---|
2xxx Messages |