TUFLOW Message 2036

From Tuflow
Jump to navigation Jump to search

TUFLOW Message
ERROR 2036 - Trying to apply a S boundary to a 2D cell already assigned a link or a H or Q boundary.

Alternate Message
NA

Message Type
ERROR

Description
Trying to apply a source flow (S) boundary to a 2D cell that has already assigned a link or a water level (H) boundary. When a water level boundary is specified on a cell, flows into and out of the cell are computed. When a S (source) or Q (flow) boundary is specified at a cell, the water level in the cell is computed. However, tt is not possible to specify both a flow and water level at a cell.

Suggestions
Separate incompatible boundary types, for example ensure the both "SX" and "HX" boundaries at not both applying to the same cell.


Up
Go-up.png 2xxx Messages