TUFLOW Message 2071

From Tuflow
Jump to navigation Jump to search

TUFLOW Message
WARNING 2071 - The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.

Alternate Message
NA

Message Type
WARNING

Description
The Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.

Suggestions
As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged.


Up
Go-up.png 2xxx Messages