ERROR 2194 - Column 1 values not ascending in ",a," table

Alternate Message
ERROR 2194 - Column 1 values not ascending in ",a," table.

Message Type
ERROR

Description
Column 1 values not ascending in a boundary condition table. Table data is output to the .tlf file and console. For a Head-Time the first column is the time data, time values should be unique and in ascending order. The same applies to all boundary condition types. For a HQ (stage-discharge, or rating curve) the height values should be increasing.

Suggestions
Check data, remove duplicate values and sort by first column. Note for TUFLOW build 2012-05-AC, consecutive flow values in automatic 2D HQ boundary tables are now automatically removed.