TUFLOW Message 3039

From Tuflow
Jump to navigation Jump to search

TUFLOW Message
ERROR 3039 - Form loss factors must be >= 0.

Alternate Message
NA

Message Type
ERROR

Description
Form loss (energy loss) factors may be applied on faces within regions. Negative form loss factors represent energy addition to the flow and are not permissible.

Suggestions
Review the applied form loss factors to ensure they all are positive.


Up