|type=[[ERROR]]
|message_desc=2D cell has a Material ID not specified in the material properties (.tmf) file.
|suggestions=Ensure that each Material ID used is included in the material properties file. This file(.tmf) links the Material ID to roughness coefficient (either Manning's N, Manning's M or Chezy). roughness coefficient can be fixed or depth varying. Check that Material ID in GIS layer (2d_mat) is correct. <br> <br>
As an example from the TUFLOW tutorial: The 2d_mat_M01_002_R.shp layer is loaded in GIS to check the material ID of objects in this layer. In the below example, there is information shown for a polygon over some water and the material ID is 4. Then check the materials file (either a .tmf or .csv) to check that the material ID is in this file and that there is a manning's n value assigned to it. <br>
[[File:ERROR2012 Check Mats.png|500px]]
|discussion_page=* [[Talk:TUFLOW Message 2012|Discuss Message 2012]]
|link3=''
| |||