Difference between revisions of "TUFLOW Message 1286"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link. |alt_msg=NA |type=ERROR |message_desc=?...')
 
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.
|suggestions=????
+
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.
 
|discussion_page=* [[Talk:TUFLOW Message 1286|Discuss Message 1286]]
 
|discussion_page=* [[Talk:TUFLOW Message 1286|Discuss Message 1286]]
 
|link3=''
 
|link3=''

Revision as of 16:23, 1 February 2019

TUFLOW Message
ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link.

Alternate Message
NA

Message Type
ERROR

Description
Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.

Suggestions
Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.


Up
Go-up.png 1xxx Messages