TUFLOW Message 1286: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link. |alt_msg=NA |type=ERROR |message_desc=?...' |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link. |
|||
|message_desc=???? |
|||
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes. |
|||
|suggestions=???? |
|||
|discussion_page=* [[Talk:TUFLOW Message 1286|Discuss Message 1286]] |
|discussion_page=* [[Talk:TUFLOW Message 1286|Discuss Message 1286]] |
||
|link3='' |
|link3='' |
||
Revision as of 16:23, 1 February 2019
TUFLOW Message
ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link.
Alternate Message
NA
Message Type
ERROR
Description
Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.
Suggestions
Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.
| Up |
|---|