Green-Ampt Infiltration Parameters: Difference between revisions
Content deleted Content added
Tuflowduncan (talk | contribs) |
No edit summary |
||
Line 129:
'''Figure 8: Sensitivity of cumulative infiltration in the Plynlimon Gwy catchment to the porosity parameter in the Green-Ampt infiltration model.'''<br>
<br>
=== Initial Moisture ===
The initial moisture value represents the fraction of the soil that is initially wet. As both initial moisture and porosity are expressed as fractions, the soil capacity is defined as the difference between them both. As such, the initial moisture should not exceed the porosity otherwise soil capacity will be set to zero with no infiltration occurring for that soil type. A WARNING of 2508 is issued if this is the case.<br>
As you increase initial moisture at the beginning of your simulation, you experience less infiltration (as you are closer to the soil capacity), therefore have more run-off and a quicker response. Figure 9 shows the degree of change to cumulative infiltration with varying initial moisture and the effect on the catchment can be seen in Figure 10.
[[File:Init moisture F10.png|600px|Figure 9: Sensitivity of cumulative infiltration in the Plynlimon Gwy catchment to the initial moisture parameter in the Green-Ampt infiltration model.]]<br>
'''Figure 9: Sensitivity of cumulative infiltration in the Plynlimon Gwy catchment to the initial moisture parameter in the Green-Ampt infiltration model.'''<br>
[[File:Init moisture F11 catchment.png|600px|Figure 10: Sensitivity of simulated flow at the Cefn-Brwn gauge location in the Plynlimon Gwy catchment to the initial moisture parameter in the Green-Ampt infiltration model.]]<br>
'''Figure 10: Sensitivity of simulated flow at the Cefn-Brwn gauge location in the Plynlimon Gwy catchment to the initial moisture parameter in the Green-Ampt infiltration model.'''<br>
== In built USDA soil type ==
The model was also run with the default in-build USDA soil types. Figure
<br>
[[File:Fig10 GA soils.png|600px|Figure
'''Figure 9: Sensitivity of simulated flow at the Cefn-Brwn gauge location in the Plynlimon Gwy catchment to the USDA soil type parameter in the Green-Ampt infiltration model.'''
<br>
|