Line 5: Line 5:
 
|message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.
 
|message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.
 
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.
 
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.
|discussion_page=* [[Talk:TUFLOW Message 1286|Discuss Message 1286]]
+
 
|link3=''
 
|link4=''
 
 
|prelink=[[TUFLOW_Message_1285|Message 1285]]
 
|prelink=[[TUFLOW_Message_1285|Message 1285]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|nextlink=[[TUFLOW_Message_1287|Message 1287]]
 
|nextlink=[[TUFLOW_Message_1287|Message 1287]]
 
}}
 
}}

Revision as of 14:44, 5 July 2022

TUFLOW Message
ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link.

Alternate Message
NA

Message Type
ERROR

Description
Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.

Suggestions
Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.


Up