Line 7:
<br>
Care should be taken when upgrading when upgrading to the 2016 version of TUFLOW if exit losses are specified on open channels - for pre 2016 versions of TUFLOW this attribute was not used for open channels.
|suggestions=Review the input form loss value per unit length and the final value of form loss applied (see the '''Form_Loss''' attribute in the <u>[[Check_Files_1d_nwk_C | 1d_nwk_C check file]]</u>) for open channels. For consistency with pre 2016 versions of TUFLOW, this should be set to 0.0 for "S" type channels.
 
|discussion_page=* [[Talk:TUFLOW Message 1132|Discuss Message 1132]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1131|Message 1131]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1133|Message 1133]]
}}