Line 3:
|alt_msg=NA
|type=[[ERROR]]
|message_desc=The '''Exit_Loss''' attribute on the 1d_nwk can be used to set a form loss per unit length of channel, the value specified is unusually high. This value is multiplied by the channel length to determine the final value applied on the channel.<br>
This functionality was introduced in the 2016 version of TUFLOW and currently only applies to "S" type (open channels).
|suggestions=Review the input form loss value per unit length and the final value of form loss applied (see the '''Form_Loss''' attribute in the [[Check_Files_1d_nwk_C | 1d_nwk_C check file]]).▼
<br>
Care should be taken when upgrading when upgrading to the 2016 version of TUFLOW if exit losses are specified on open channels - for pre 2016 versions of TUFLOW this attribute was not used for open channels.
▲|suggestions=Review the input form loss value per unit length and the final value of form loss applied (see the '''Form_Loss''' attribute in the <u>[[Check_Files_1d_nwk_C | 1d_nwk_C check file]]</u>) for open channels. For consistency with pre 2016 versions of TUFLOW, this should be set to 0.0 for "S" type channels.