TUFLOW Message 1262: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(5 intermediate revisions by 2 users not shown)
Line 1:
{{TUFLOW_Message
|tuflow_message=WARNING 1262 - Manning's n value of ",a,"<Manning's n value> for channel ",a,"<Channel ID> is unusually low or high.
|alt_msg=NA
|type=[[WARNING]]
|message_desc=Manning's n value assigned to channel, is outside normal range.
|suggestions=Check Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). This can occur if a the multiplication value is set to a typical ManningsManning's value (e.g. 0.04) and materials are defined in the XZM cross-section. In this case the ManningsManning's n value may become 0.04 x 0.04 = 0.0016!
 
|discussion_page=* [[Talk:TUFLOW Message 1262|Discuss Message 1262]]
 
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1261|Message 1261]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1264|Message 1264]]
}}