Line 5: | Line 5: | ||
|message_desc=Manning's n value assigned to channel is outside normal range. |
|message_desc=Manning's n value assigned to channel is outside normal range. |
||
|suggestions=Check Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). This can occur if a the multiplication value is set to a typical Manning's value (e.g. 0.04) and materials are defined in the XZM cross-section. In this case the Manning's n value may become 0.04 x 0.04 = 0.0016! |
|suggestions=Check Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). This can occur if a the multiplication value is set to a typical Manning's value (e.g. 0.04) and materials are defined in the XZM cross-section. In this case the Manning's n value may become 0.04 x 0.04 = 0.0016! |
||
|discussion_page=* [[Talk:TUFLOW Message 1262|Discuss Message 1262]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_1261|Message 1261]] |
|||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_1264|Message 1264]] |
|||
}} |
}} |
Latest revision as of 16:00, 22 December 2022
TUFLOW Message
WARNING 1262 - Manning's n value of <Manning's n value> for channel <Channel ID> is unusually low or high.
Alternate Message
NA
Message Type
WARNING
Description
Manning's n value assigned to channel is outside normal range.
Suggestions
Check Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). This can occur if a the multiplication value is set to a typical Manning's value (e.g. 0.04) and materials are defined in the XZM cross-section. In this case the Manning's n value may become 0.04 x 0.04 = 0.0016!