Difference between revisions of "TUFLOW Message 1286"
Jump to navigation
Jump to search
(One intermediate revision by the same user not shown) | |||
Line 5: | Line 5: | ||
|message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link. | |message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link. | ||
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes. | |suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes. | ||
− | + | ||
− | |||
− | |||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 10:21, 23 December 2022
TUFLOW Message
ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link.
Alternate Message
NA
Message Type
ERROR
Description
Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.
Suggestions
Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.
Up |
---|
1xxx Messages |