Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link. |alt_msg=NA |type=ERROR |message_desc=?...'
 
No edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 3: Line 3:
|alt_msg=NA
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc= Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.
|message_desc=????
|suggestions=Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.
|suggestions=????

|discussion_page=* [[Talk:TUFLOW Message 1286|Discuss Message 1286]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1285|Message 1285]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1287|Message 1287]]
}}
}}

Latest revision as of 10:21, 23 December 2022

TUFLOW Message
ERROR 1286 - All 1D nodes within 1D QT region to be assigned a flow are a H boundary or a 2D SX link.

Alternate Message
NA

Message Type
ERROR

Description
Flow from 1D QT region can't be applied to a H boundary or a 2D SX link.

Suggestions
Correct the application of 1D QT region. This Error can also occur when a specific flag (C, O or P) is applied to an incorrect 1D node. For example, if a "P" flag for direct flow into the bottom of pits channels is applied to a 1D QT region containing only open channel nodes.


Up
1xxx Messages