TUFLOW Message 2036: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
Line 6: Line 6:
|suggestions=Separate incompatible boundary types, for example ensure the both "SX" and "HX" boundaries at not both applying to the same cell.
|suggestions=Separate incompatible boundary types, for example ensure the both "SX" and "HX" boundaries at not both applying to the same cell.



|prelink=[[TUFLOW_Message_2035|Message 2035]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2037|Message 2037]]
}}
}}

Latest revision as of 11:02, 23 December 2022

TUFLOW Message
ERROR 2036 - Trying to apply a S boundary to a 2D cell already assigned a link or a H or Q boundary.

Alternate Message
NA

Message Type
ERROR

Description
Trying to apply a source flow (S) boundary to a 2D cell that has already assigned a link or a water level (H) boundary. When a water level boundary is specified on a cell, flows into and out of the cell are computed. When a S (source) or Q (flow) boundary is specified at a cell, the water level in the cell is computed. However, tt is not possible to specify both a flow and water level at a cell.

Suggestions
Separate incompatible boundary types, for example ensure the both "SX" and "HX" boundaries at not both applying to the same cell.


Up
2xxx Messages